A comparative planning study of step-and-shoot IMRT versus helical tomotherapy in a model patient

Yong Nam Kim, Soo Kon Kim, Kyoungkeun Jeong, Chang Geol Lee, Ki Chang Keum, Ik Jae Lee, Jaeho Cho

Research output: Contribution to journalArticlepeer-review

Abstract

In order to assess the potential benefit of being able to use non-coplanar beams in a step-andshoot intensity-modulated radiotherapy (ssIMRT) differently from helical tomotherapy (HT), we performed a comparative planning evaluation in a model patient whose clinical target volumes enclosed critical normal tissue lying in the same plane. A patient with extensively relapsed malignant lymphoma in the circumferential chest wall was selected for comparison. Multiple, separated gross tumors were delineated, and the clinical target volume included the circumferential chest wall containing gross tumor volumes so that the critical organ, the right lung was fully enclosed. Three types of plans were analyzed; the first one was ssIMRT using only coplanar beams, the second was ssIMRT using non-coplanar beams, and the third was HT. The obtained results showed that dose homogeneity inside the gross tumor volume was better in the case of HT than noncoplanar ssIMRT and coplanar ssIMRT. However, the volume fraction of the right lung receiving a high dose was much smaller in the noncoplanar ssIMRT. As far as the dose to the clinical target volume (CTV) fully enclosing the right lung is concerned, not only the dose coverage of the CTV but also the dose homogeneity and conformity in the noncoplanar ssIMRT was better than in both of HT and the coplanar ssIMRT. We can conclude that appropriate isodose coverage for a complex target, which fully encloses a critical organ lying in the same plane, can be achieved by using a non-coplanar beam arrangement with no enforced penalty of higher dose to a critical organ.

Original languageEnglish
Pages (from-to)1481-1485
Number of pages5
JournalJournal of the Korean Physical Society
Volume63
Issue number7
DOIs
Publication statusPublished - 2013 Oct

Bibliographical note

Funding Information:
the Nuclear Science Research Program (Grant No. NRF-2011-0018791) through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science, and Technology of the Government of South Korea.

All Science Journal Classification (ASJC) codes

  • Physics and Astronomy(all)

Fingerprint

Dive into the research topics of 'A comparative planning study of step-and-shoot IMRT versus helical tomotherapy in a model patient'. Together they form a unique fingerprint.

Cite this